3-phase network parameter analyzer
Failed to load pickup availability
Online payment by card – after placing your order, you will be redirected to the payment gateway and you will receive payment confirmation by email.
Cash on delivery – payment will be made to the courier of the transport company in accordance with the payment terms.
Bank transfer – we will send a pro forma invoice to your email address no later than the next business day, which will include the account number for payment.
On an invoice with deferred payment – this payment method is available to partners who have signed a framework agreement with our company.
If you wish to use the latter two payment methods, please contact our manager who will provide you with instructions on how to receive an invoice with or without VAT.
The electrical devices we supply meet high quality standards, come with a 24-month warranty, and meet all EU requirements. In the event of a complaint, we do not charge any fees for returning goods.
3-phase network analyzer / network analyzer / network parameter meter - multifunctional digital panel meter, indicator of current, voltage, frequency, and total power, with two relay outputs and a digital input, RS485 ModBus RTU - TPM-01ESH Manufacturer TENSE (Turkey)
The multifunctional power network analyzer is designed for accurate measurement of three-phase network parameters.
Power analyzers are designed for measuring and monitoring electrical values. Using communication functions, energy measurements can be independently monitored and reported.
Main advantages:
- RS485 Modbus RTU (1200-38400bps)
- 3-phase voltage transformer and 3-phase current transformer.
Displays voltage and current harmonics up to the 31st harmonic
Shows active power per phase (P)
Shows reactive power per phase (Q, inductive and capacitive)
Shows apparent power per phase (S)
Shows Cosφ values and power factor for each phase
Displays phase-to-neutral voltage, line voltage (V), and current (I) values for each phase, measurement frequency
Displays total values of active energy import and export (ΣkWh)
Displays total values of inductive and capacitive reactive energy (ΣkVArh)
Displays minimum and maximum values, max. demand
2 relay outputs, 1 digital input
Event register (high/low voltage/current, voltage/current asymmetry, THD-I)
The menu is password protected.
Usually this network analyzer is used with current transformers - 60/5 75/5 100/5 150/5 200/5 250/5 300/5 400/5 500/5 600/5 800/5 1000/5 1500/5 or similar. Such transformers can be purchased in our online store. If the analyzer is to be connected to the ModBus bus, we will send the register table with ModBus addresses upon request.